FC150 Series Humidifiers

   

 

 

 

 

 

 


 

Model Number

A

B Nom.

C

D

inch mm inch mm inch mm inch mm

FC150-480-7PP

11.5 292.1 7 177.8 6.75 171.5 4.3 109.2
FC150-480-10PP 14.5 368.3 10 254 9.75 247.7 7.3 185.4

FC150-480-15PP

19.5 495.3 15 381 14.75 374.7 12.3 312.4
Water-to-Gas Performance Chart Gas-to-Gas Performance Chart

 

Materials of construction:

          Housing –  Polypropylene

          Seals – EPDM (peroxide cured)

          Tube bundle headers – Thermoset polyurethane

          Membrane tubing – Nafion®

Operating fluid pressure range: 0 to 172 kPa ( 0 to 25 psig) @ 80°C (176°F)

Operating fluid temperature range: 1 to 80°C (33 to 176°F)

Pressure differential on tubing: 35 kPa (0 to 5 psid) @ 80°C (176°F)

    Negative pressure differential will collapse tubing and must be avoided

Storage temperature range: -30 to 60°C (-22 to 140°F)

 

 
 

Perma Pure LLC. 8 Executive Drive, Toms River, New Jersey  08755

Copyright 2005 | All rights reserved