Baldwin-Series Direct Extractive Filter Probes
Hazardous Area Applications
Class 1 Division 1 & Class 1 Division 2

Baldwin's Direct Extractive Filter Probes feature an advanced design to extract sample gas and remove particulate while preventing condensation prior to the gas sample entering the heated sample line.

New Machine-Lathed Sure-Lock™ Filter Assembly
Baldwin's new Sure-Lock filter assembly is precision machined and features a unique design to help ensure proper insertion into the assembly and to reduce the possibility of leaks. The filter head is inserted into a notch in the assembly to ensure proper alignment before locking it in place. The o-rings are tightened under compression, rather than being located on the sides of the filter head, to reduce the risk of leakage.







  • Available for Class 1 Division 2 and Class 1 Division 1 applications

  • Sure-lock filter reduces risk of leakage

  • Range of filter elements designed for various applications

  • Available with air blowback system

 

Options Available:

  • Schedule 40, Schedule 80, Hastelloy, and Durinert+ stinger probes
  • Sintered stainless steel, screen mesh, ceramic, glass fiber, and Hastelloy filter elements
  • Air blowback system with 115 VAC, 230 VAC, 12 VDC, or 24 VDC solenoid
  • Solenoid to close sample line when blowback is initiated
  • Gas cooling spool piece for high temperature gas sources
  • Various size flanges
  • Durinert® or Teflon coated filter assembly option for corrosive gas streams
  • NEMA 4X stainless steel or fiberglass enclosure

Model Specifications

Model Area Classification Blowback Filter Assembly
Temp Control
Enclosure Dimensions*
HWD
Weight
34 C-Z Class 1, Div 2
Groups B,C,D
2-way
solenoid
External
Regulated
NEMA 4X
306 stainless steel
14x20x8 in
36x51x20 cm
40 lbs
18 kg
34 C-R-Z Class 1, Div 2
Groups B,C,D
2-way
solenoid
Self Regulated NEMA 4X
306 stainless steel
14x20x8 in
36x51x20 cm
40 lbs
18 kg
33 XP Class 1, Div 1
Groups B,C,D
N/A Self
Regulated
UL® Classified Aluminum 8x8x11 in
20x20x28 cm
30 lbs
14 kg
34 XP Class 1, Div 1
Groups B,C,D
2-way
solenoid
Self  Regulated UL® Classified Aluminum 8x8x11 in
20x20x28 cm
33 lbs
15 kg

*Excluded probe stinger and heat-shrink boot.

Filter Assembly Sure-Lock, 316 stainless steel
Filter Element Types 10 micron sintered SS (standard)
5, 20 micron sintered SS
2 micron ceramic
2 micron SS screen mesh
0.1 micron glass
0.7 micron glass / TFE coated
2 micron Teflon
Probe Lengths 18 inch, 1, 2, 3, 4, 5 foot
Probe Materials Schedule 40, Schedule 80, Hastelloy (optional)
Connections 1 1/4" male pipe nipple mount; 1/2" female pipe thread for stinger; 1/2" conduit entry for Class 1 Division 1 models
Connectors 1/4" cal gas, 3/8" blowback, 3/8" sample line
Thermocouple Type K
Heater Type Silicone rubber blanket w/metal snap closures, 100W (standard)
Heater bands, 350W (optional upgrade)
Heat-shrink Boot* 7" length, 2.75" min expanded I.D. nose
O-rings Viton®
Gaskets Graphoil
Enclosure Insulation 1/8" thick silicone, medium density
Calibration Gas Requirement 20 psig, 6-10 LPM
Probe Operating Temperature 375°F (190°C)
Input Voltage 115 (230 optional) VAC, 50/60 Hz

*Class 1, Division 2 probes require air purge line

Blowback System Specifications (Models 34C-Z, 34C-R-Z, 34XP)

Blowback Duration 5 sec standard
Instrument Air for Blowback Min50 psig, Max 90 psig
Blowback Accumulator Tank 16 ga. SS, 4x8 inch cylinder
Blowback Flowrate 14 scfh
Blowback Valve 120 VAC (standard)
230 VAC, 12VDC, 24 VDC (optional)


Baldwin™ is a Trademark of Perma Pure LLC
Viton® is a Registered Trademark of DuPont
Graphoil® is a Registered Trademark of Union Carbide Corporation

Filter probes - Hazardous
Operation Manuals (pdf)
Model 34C-Z  
Model 34C-R-Z  
Model 33XP Manual
Model 34XP Manual
   

Click here for ordering information, part number & option codes