Baldwin-Series Classic Thermo-Electric Cooler

 

A Revolution in Gas Sample Conditioning

  • Monitor & control your gas sample handling system remotely via modbus over TCP/IP or custom Windows application over a network

  • Local monitoring & control on a jumbo 20line LCD screen with multi-colored LEDs

  • Precise digital calibration accuracy and immunity to electrical noise and interference

  • EZ-Clean™ twist-apart heat exchangers

Key Features:

  • Remote monitoring and control of heated filter probe, sample line, and sample conditioning system
  • Custom Windows application to monitor and control over the Internet or LAN
  • Jumbo 20line LCD display with multi-colored LEDs
  • Alarm notification of over/under temperature, thermocouple failure, and water slip
  • Alarm relay protects analyzers from water slip.
  • Eliminates the complexity of separate temperature controllers
  • Extra thermocouple inputs and outputs available
  • Optional Durinert® treated heat exchangers for low NOx and acidic applications
  • Operates with 115, 230 VAC, 12VDC, 15VDC, or 24VDC
  • Backed by our 1-year limited warranty

Model Comparison
5000 Series General Purpose and
5000XP Series Class 1 Division 2 Groups A,B,C,D

Model Std.
Capacity
Heat Exchangers Dimensions Weight
Passive Active
e5300 0-3 LPM
0-6 SCFH
1 x 5in. 1 x 5in. 11 x 7 x 11 in. HWD
29 x 18 x 29 cm HWD
20 lbs
9 kg

Digital Model e5300, Single stream system; 2 x 5" heat exchangers connected in series(1 passive/1 active), 1-3 lpm, w/temperature display;water slip/temp. alarm relay.(no ethernet board, no accessory board,no isolated output board.) General Purpose.
 

e5400 3-4 LPM
6-8 SCFH
  2 x 5 in. 11 x 7 x 11 in. HWD
29 x 18 x 29 cm HWD
20 lbs
9 kg

Digital Model e5400, with 2 active 5" heat exchangers, w/temperature display;water slip/temp.alarm, 4-7 lpm. (no ethernet board, no accessory board,no isolated output board.) General Purpose.
 

e5500 4-7 LPM
8-15 SCFH
1 x 10 in. 1 x 10 in. 14 x 13 x 13 in. HWD
36 x 33 x 33 cm. HWD
37 lbs
17 kg

Digital Model e5500, Single channel system; 2 x 10" heat exchangers connected in series only(1 passive, 1 active), 4-7 lpm (8-15 scfh). Single-channel w/temperature display;water slip/temp. alarm relay. 115VAC; General Purpose
 

e5500 XP 4-7 LPM
8-15 SCFH
1 x 10 in. 1 x 10 in. 14 x 13 x 13 in. HWD
36 x 33 x 33 cm. HWD
37 lbs
17 kg

Digital Model e5500XP, 110VAC. Class I Div 2, Groups A,B,C & D; Single stream system; 2 x 10" heat exchangers connected in series (1 passive/1 active), 4-7 lpm, w/temperature display; water slip/temp. alarm relay. (no ethernet board, no accessory board, no isolated output board). Class 1 Division 2 Groups A,B,C,D
 

e5800 7-10 LPM
15-21 SCFH
  2 x 10 in 14 x 13 x 13 in HWD
36 x 33 x 33 cm HWD
37 lbs
17 kg

Digital Model 5800, Dual Channel (Active/Active), 115VAC, with 2 active 10" heat exchangers,w/temperature display; water slip/temp. alarm relay. 7-10 lpm.(No ethernet board, no accessory output controller, no isolated output.)115VAC; General Purpose.
 

e5800XP 7-10 LPM
15-21 SCFH
  2 x 10 in 14 x 13 x 13 in HWD
36 x 33 x 33 cm HWD
39 lbs
18 kg

Digital Model e5800XP, 110VAC. Class I Div 2,Groups A,B,C & D; Dual stream system; 2 x 10" active heat exchangers connected in series or parallel, 7-10 lpm,w/temperature display; water slip/temp. alarm relay. (no ethernet board, no accessory board, no isolated output board). Class 1 Division 2 Groups A,B,C,D
 

e5900 10-20 LPM
21-42 SCFH
2 x 10 in 2 x 10 in 14 x 13 x 13 in. HWD
36 x 33 x 33 cm. HWD
39 lbs
18 kg

Digital Model 5900, 115VAC. Includes: 4x 10" heat exchangers (Passive/Active, Passive/Active), single- or dual-stream config w/temperature display; water slip/temp. alarm relay. 10-20 lpm. (no ethernet board, no accessory board, no isolated output board). General Purpose.
 

e5900XP 10-20 LPM
21-42 SCFH
2 x 10 in. 2 x 10 in 14 x 13 x 13 in. HWD
36 x 33 x 33 cm. HWD
41 lbs
19 kg

Digital Model e5900XP, 110VAC. Class I Div 2, Groups A,B,C & D; Single or Dual stream system; 4 x 10" heat exchangers (Passive/Active, Passive/Active), 10-20 lpm, dual display & relay. (no ethernet board, no accessory board, no isolated output board). Class 1 Division 2 Groups A,B,C,D
 

Classic Cooler

pdf Brochure