FC-Series Humidifiers
The Perma Pure line of FC-Series Nafion gas humidifiers operate as
either water-to-gas humidifiers or gas-to-gas moisture exchangers. The
water-to-gas humidifiers have water on one side of the tube wall and the
gas to be humidified on the other.
| Series |
# of Nafion Tubes |
Ports4 |
Max. Pressure |
Gas-to-Gas1 |
Water-to-Gas2 |
|
Flow Rate Recommendation |
| FC125 |
240 |
1/2" FNPT |
to 25 psig |
15-75 slpm |
< 150 slpm |
| FC150 |
480 |
3/4" FNPT |
to 15 psig |
35-150 slpm |
200-300
slpm |
| FC200 |
780 |
1" FNPT |
to 10 psig |
50-300 slpm |
300-450
slpm |
| FC300 |
1660 |
1-1/2" FNPT |
to 5 psig |
120-625 slpm |
450-1000
slpm |
| FC300HP |
1660 |
1-1/2" FNPT |
3 barg |
120-625 slpm |
450-1000
slpm |
| FC400 |
2500 |
1" FNPT3 |
< 5 psig |
200-1000 slpm |
1000-1500
slpm |
| FC600 |
7000 |
2" FNPT |
< 5 psig |
500-2500 slpm |
1500 + slpm |
Maximum differential pressure, with tube > shell side, 5
psig; Max. temperature 90°C
The
use of metal fittings is
not recommended with FC Series Humidifiers.
Nylon, ABS or polypropylene fittings are suggested. |
1 Flow rate recommendations based upon an approach temperature
between 4-6 degrees. The optimal dry air inlet temperature range is
between 35 and 55°C. 2 Water-to-gas flow rate is based upon a
80-85%RH. See actual performance curves for specific flow rates. Note
that the gas pressure must be higher than the water pressure.
3 2" ports available as option. 4
When ordering, specify port orientation as same side or 180
degree rotation. |