FC150-480 Series

 

Housing material: Polypropylene

Model Number

A

B

C

D

Flow Rate (slpm)

Gas-to-Gas Water-to-Gas
Approach Temp.* Flow vs Dewpoint

4 deg

6 deg

9 deg

FC150-480-7PP

11.50" 7" 6.75" 4.3" 35 84 112

FC150-480-10PP

14.50" 10" 9.75" 7.3" 50 120 160
FC150-480-15PP 19.50" 15" 14.75" 12.3" 75 195 260

Click on the model number for a .dwf drawing

Click on chart icon for water-to-gas performance data

* The performance information for the gas-to-gas units are expressed as the flow rate of air (slpm) in relation to the approach dew point temperature. The approach temperature is defined as the difference between the cathode exhaust stream entering the humidifier and the humidifier exhaust stream going to the stack. For example, if the cathode exhaust dew point entering the humidifier is 67° and the humidifier generates a dew point of 61°, it would have been sized for a 6° approach temperature.