FC300-1660 Series

 

Housing material: Black ABS

Model Number

A


B
Nom.
C

D

Flow Rate (slpm)

Gas-to-Gas Water-to-Gas
Approach Temp. * Flow vs Dewpoint

4 deg

6 deg

9 deg

FC300-1660-7ABS

12.10" 7" 5.60" 2.1" 121 291 387

FC300-1660-10ABS

15.10" 10" 8.60" 5.1" 173 415 553
FC300-1660-15ABS 20.10" 15" 13.60" 10.1" 259 623 830 N/A
Pressure drop data  

Click on the model number for a .dwf drawing

Click on the chart icon for water-to-gas performance data

* The performance information for the gas-to-gas units are expressed as the flow rate of air (slpm) in relation to the approach dew point temperature. The approach temperature is defined as the difference between the cathode exhaust stream entering the humidifier and the humidifier exhaust stream going to the stack. For example, if the cathode exhaust dew point entering the humidifier is 67° and the humidifier generates a dew point of 61°, it would have been sized for a 6° approach temperature.