FF-250 Series Filter Maintenance

All coalescing/ particulate filters should be checked regularly to ensure that the element is in good condition. The element should be replaced if it appears to be dirty or begins to cause a flow restriction in the system.

  1. Loosen the bolt on the bottom of the filter housing.
  2. Pull the assembly apart gently and remove the filter element.
  3. Install the glass shell on the bottom piece.
  4. Place the new element into the grooves in the top and bottom of the housing. Make sure that the element is seated correctly and parallel to the glass shell.
  5. Inspect the o-rings on the top and bottom pieces and on the center bolt.
  6. Carefully mate the bottom assembly onto the top piece. A slight twisting motion may be required to allow the shell to slip over the o-ring seal.
  7. Visually make sure that the element is seated correctly in the top groove.
  8. Replace the bolt through the hole in the bottom piece and screw clockwise into the tip piece. Be careful not to over-tighten the center bolt. It should be just tight enough as to not vibrate loose. Over-tightening will not help the filter to seal and will not increase performance. It may cause the glass shell to crack or cause other damage.

FF-250 exploded view

1 Top
2 Element
3 O-Ring
4 Shell
5 Bottom
6 O-Ring
7 Thumbscrew