Performance
Listed below are the performance curves for the MH-070 Humidifiers.
Perma Pure offers an MH-110 which has a slightly higher ID. The
performance is similar. The MH-110 could expect to see about a 3 degree
higher outlet dew point than the MH-070. The MH-110 should be chosen
when a lower pressure drop is desired.


The MH-Series humidifier performance
curves were performed under the following conditions:
- Water was supplied to the shell
side of the humidifier with a static pressure of 5" water column and
no flow.
- The water temperature was
controlled at the levels noted on the curves.
- The humidifier housing was
insulated.
- The air was passed through the
tube side of the humidifier at atmospheric pressure.
- The inlet air stream was at 24°C
and <-40°C dew point.
- Measurements were taken with an EG&G
chilled mirror dew point monitor.
For setup instructions, see the pdf
Manual.
|