Scientific, Research & Industrial

Medical

Environmental

Fuel Cells

Company

Technology

Support

Hazardous Area

Baldwin™-Series Direct Extractive Filter Probes

Hazardous Area Applications
Class 1 Division 1 & Class 1 Division 2

Baldwin’s Direct Extractive Filter Probes feature an advanced design to extract sample gas and remove particulate while preventing condensation prior to the gas sample entering the heated sample line.

ha_zpurge probeNew Machine-Lathed Sure-Lock™ Filter Assembly
Baldwin’s new Sure-Lock filter assembly is precision machined and features a unique design to help ensure proper insertion into the assembly and to reduce the possibility of leaks. The filter head is inserted into a notch in the assembly to ensure proper alignment before locking it in place. The o-rings are tightened under compression, rather than being located on the sides of the filter head, to reduce the risk of leakage.

  • Available for Class 1 Division 2 and Class 1 Division 1 applications

  • Sure-lock filter reduces risk of leakage

  • Range of filter elements designed for various applications

  • Available with air blowback system

Options Available:

  • Schedule 40, Schedule 80, Hastelloy, and Durinert+ stinger probes
  • Sintered stainless steel, screen mesh, ceramic, glass fiber, and Hastelloy filter elements
  • Air blowback system with 115 VAC, 230 VAC, 12 VDC, or 24 VDC solenoid
  • Solenoid to close sample line when blowback is initiated
  • Gas cooling spool piece for high temperature gas sources
  • Various size flanges
  • Durinert® or Teflon coated filter assembly option for corrosive gas streams
  • NEMA 4X stainless steel or fiberglass enclosure

Model Specifications

Model Area Classification Blowback Filter Assembly
Temp Control
Enclosure Dimensions*
HWD
Weight
33 XP Class 1, Div 1
Groups B,C,D
N/A Self
Regulated
UL® Classified Aluminum 8x8x11 in
20x20x28 cm
30 lbs
14 kg

*Excluded probe stinger and heat-shrink boot.

Filter Assembly Sure-Lock, 316 stainless steel
Filter Element Types 10 micron sintered SS (standard)
5, 20 micron sintered SS
2 micron ceramic
2 micron SS screen mesh
0.1 micron glass
0.7 micron glass / TFE coated
2 micron Teflon
Probe Lengths 18 inch, 1, 2, 3, 4, 5 foot
Probe Materials Schedule 40, Schedule 80, Hastelloy (optional)
Connections 1 1/4″ male pipe nipple mount; 1/2″ female pipe thread for stinger; 1/2″ conduit entry for Class 1 Division 1 models
Connectors 1/4″ cal gas, 3/8″ blowback, 3/8″ sample line
Thermocouple Type K
Heater Type Silicone rubber blanket w/metal snap closures, 100W (standard)
Heater bands, 350W (optional upgrade)
Heat-shrink Boot* 7″ length, 2.75″ min expanded I.D. nose
O-rings Viton®
Gaskets Graphoil
Enclosure Insulation 1/8″ thick silicone, medium density
Calibration Gas Requirement 20 psig, 6-10 LPM
Probe Operating Temperature 375°F (190°C)
Input Voltage 115 (230 optional) VAC, 50/60 Hz

*Class 1, Division 2 probes require air purge line

Blowback System Specifications (Models 34C-Z, 34C-R-Z, 34XP)

Blowback Duration 5 sec standard
Instrument Air for Blowback Min50 psig, Max 90 psig
Blowback Accumulator Tank 16 ga. SS, 4×8 inch cylinder
Blowback Flowrate 14 scfh
Blowback Valve 120 VAC (standard)
230 VAC, 12VDC, 24 VDC (optional)

Baldwin™ is a Trademark of Perma Pure LLC
Viton® is a Registered Trademark of DuPont
Graphoil® is a Registered Trademark of Union Carbide Corporation